John Lewis JLBIGH603 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
or the earth symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
Assembly
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
min. 100 mm
30 mm
4
80
mm
min. 600 mm
4.
50 mm
400 mm
If a furniture unit is installed at a
distance of 400 mm above the
hob, there must be a minimum
safety distance of 50 mm to the
left or right from the edge of
the hob.
5.
6.
7.
Hob User Manual