9
Extraction (Ducted)
The cooker hood is more effective when installed in the
extraction mode (ducted to the outside).
Venting kits may be purchased through your retailer or
DIY store, and must be evacuated through an outside
vent of ø120 (5ins).
The ducting used must be manufactured from fire
retardent material conforming to the relevant British
Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside
the charcoal filter must be removed.
Fitting the Ducting
• T
he Ø120 mm ducting spigot must be fitted into the
apperture on top of the cooker hood and sealed
to make an air tight connection.
• For the best performance use the shortest possible run
of ducting and we recommend the use of rigid pipe in
preference to flexible hose as this will improve the flow
of air while reducing turbulence, which causes noise and
a loss of performance.
• If the room where the cooker hood is to be used contains
a fuel burning appliance such as a central heating boiler,
then its flue must be be of the room sealed or balanced
flue type.
• If other types of flue or appliances are fitted ensure that
there is an adequate supply of air to the room.
• The cooker ducting when fitted in the extraction mode
must never be connected to central heating flues, radiators
or water heaters.
Recirculation Mode
The charcoal filter must be fitted for recirculation and the
slide control must be in the recirculation position.